completed date on log listed as 2026 but it seems like a typo. building built in 2025 so ending date was changed to 2025.
Well Intake Opening Type
Open_End
Screen Type
Not Available
Screen Mesh Size
Not Available
Screen Start Depth
Not Available
Screen Stop Depth
Not Available
Perforated
No
Start: Not Available
Stop: Not Available
Start: Not Available
Stop: Not Available
Perforation Description
Not Available
Gravel Packed
No
Gravel Depth
Start: Not Available
Stop: Not Available
Note:
Not Available
Casing Type
steel
Casing Thickness (in)
.25
Casing Depth (ft)
239
Casing Stickup (ft)
2
Casing Diameter (in)
6
Liner Type
Not Available
Liner Diameter (in)
Not Available
Liner Depth (ft)
Not Available
Comments
Not Available
Static Water Depth (ft)
173
Pumping Level & Yield
10
Recovery Rate
10
Method of Testing
airlift
Development Method
Not Available
Duration
Not Available
Type
bentonite granules
Volume
2 bags
Depth (ft)
From: 0
To: Not Available
Pump Install Date
Not Available
Pump Model
Not Available
Pump Brand Name
Not Available
Final Pump Intake Depth (ft)
Not Available
Pump Size (hp)
Not Available
Well Disinfected Upon Completion
Yes
Method of Disinfection
chlorine tablets
Water Quailty Tested
No
Water Quality Params Tested
Not Available
measured from ground surface
0ft to 1ft
organics and silt
1ft to 28ft
gravelly silt
28ft to 121ft
sandy silt
121ft to 198ft
gravelly silt
198ft to 211ft
silt
211ft to 236ft
silty water sand and gravel
236ft to 239ft
water sand and gravel silty
Disclaimer: This page is provided as a public service by the Alaska Division of Mining, Land and Water. The Division makes NO representation regarding well location,
completeness or accuracy of the data in the database or data extraction procedures provided. Data are provisional. The user assumes total responsibility for verification.